SchücoFlam® E

  • ​​​​Fire protecting glass for 30 minutes fire resistance
  • Clear fire protection glass for room separation (E30)
  • Two-sided safety glazing according to EN 12600 - class 1(C)1 – D:TRAV Kat. C2
  • Heat-Soak*-tested for permanent reliability as standard
  • Heat-Soak is standard order, order without Heat-Soak is possible
  • Improved noise insulation (Silence)
  • Increased safety function and property protection
  • Sun protection
  • Can be decorated e.g. sandblasting​

Product description, properties and application

SchücoFlam® E is suitable for both internal and external use and in addition to its fire-resisting capability also offers optimal smoke protection properties. In contrast to normal pre-stressed glass, this fire-protecting safety glass has considerably better mechanical and thermal properties for optimal person and property protection in the event of fire.
In the case of a fire, SchücoFlam® E offers a high-class protection against the penetration of fire, smoke and hot toxic gases. In the event of a fire, the glazing remains transparent and intact and allows the people in the building to make a safe exit. The emergency services will become aware of the source of danger rapidly and can start immediately with smoke removal as well as well as firefighting and rescue activities.

 

System features

SystemSecurity systems
MaterialGlass
TypesFixed glazing
SecurityBurglar resistant RC2
Burglar resistant RC3
SurfaceOther
Sound insulationincreased sound insulation 38 - 45 dB
Key figuresFire protection class: E30

Exterior window element with surrounding fixed fields
For openable elements, a CE marking can be created.                                                     CE or ÜA          CE from 01.10.2019 "a must"
If an openable element has been tested in an associated supporting structure,
(same glass, same construction) and left or right or up or down a fixed field is
connected, then it is a portal → CE                                                                                   CE or ÜA          CE from 01.10.2019 "a must"
If further fixed elements are installed, then these are to be marked ÜA .                          ÜA

Exterior window element standing alone
Marked with either CE or ÜA, where: CE as a "can" rule                                                   CE or ÜA          CE from 01.10.2019 "a must"

Exterior door element standing alone
Marked with either CE or ÜA, where: CE as a "can" rule                                                   CE or ÜA          CE from 01.10.2019 "a must"

Exterior door element with Fixed Panel (as Portal)
Schüco ADS 80 FR60: see order catalogue chapter "outdoor application"                      CE or ÜA          CE from 01.10.2019 "a must"
Schüco ADS 80 FR30: Permitted based on the information in Schüco ADS 80 FR60      CE or ÜA          CE from 01.10.2019 "a must"
If further fixed elements are installed, then these are to be marked ÜA .                          ÜA

Façade element with insert element
If an external (door) element has been tested together with the façade, then                  CE or ÜA          CE from 01.10.2019 "a must"
the supporting structure is an essential component. Door CE ("can"), Façade CE

Additional information on façades
A special feature in AT is that there are no complete fire protection façades, but usually only sections.
This means that in these cases a ÜA marking is required.
Open elements with a closed system cannot be checked and a CE marking is therefore inadmissible (e.g. balconies).