Schüco ADS 80 FR 30 / EI30

  • Narrow profile face widths
  • Fully tested door-wall range, incl. fittings
  • Stable five-chamber hollow profiles, with construction depth of 80 mm
  • Clear door passageway height allowed up to 2988 mm
  • Maximum glass sizes 1400 mm x 3000 mm
  • Element heights of up to 4500 mm possible
  • Quick clampable fastening of fittings
  • Door handles can be used in stainless steel
  • Multifunctional door for fire and smoke protection and Burglary protection rating up to RC 3
  • Access control and escape door security possible
  • Efficient production through door versions without fire protection insulators
  • Non-jamming design possible 

Schüco Door ADS 80 FR 30 for 30 minute fire resistance

Schüco Door ADS 80 FR 30 meets all the requirements of fire resistance classes EI30 and EW30.
The series consists of 5-chamber hollow profiles with a construction depth of 80 mm, also suitable for spacious clear passageway dimensions.
Schüco Doors ADS 80 FR 30 can be used for additional requirements of building security and automation: Burglary protection rating up to RC 3, anti-panic function, crash safety, access control and soundproofing can be implemented.
Schüco Doors ADS 80 FR 30 can be implemented as non-jamming doors. This is enabled by the use of profile integrated door closers with freewheel function. The non-jamming doors can be easily operated by small children or the elderly. ​

 

System features

ProduktDoors
Security systems
Building extension
WerkstoffAlumínium
EnergieThermally insulated (Uf ≤ 2,0)
ProduktTypFixed glazing
Front door inside
Front door outside
Panic front door inside
Object door openout
Supply air
SicherheitsmerkmaleBurglar resistant RC2
Burglar resistant RC3
Fire protection
Protection class
FunktionMotorisable
Controllable
Comfort control
Radio system
Emergency Exit Control
Emergency Exit Lock
Panic function
Self-closing function
SteuerungManuell switchable
Electric switchable
Gestaltung/DesignStandard
OberflächeAlu crude (refinementable)
Schallschutzincreased sound insulation 38 - 45 dB
Key figuresThermal insulation Uf in W/m²K von: -1,0
Thermal insulation Uf in W/m²K bis: -1,0
Schalldämmung Rw,p in dB von: -1,0
Schalldämmung Rw,p in dB bis: -1,0
Einbruchhemmung RC von: RC2
Einbruchhemmung RC bis: RC3
Pulver: all Variations
Eloxal: all Variations
Nasslack: all Variations
Edelstahllook: all Variations
Feuerschutzklasse: EI30
Rauchschutzklasse: Sm

Schauraum

​EN 1125 Panic plunger rods may be withdrawn in the base area for glass doors by breaking the glass and/or by skilful wire feeding, and were therefore inadmissible in combination with burglary protection.

As a solution to this dilemma, the use of shatter-proof glass made of polycarbonate or the use of an electrically lockable panic bar is offered.


Originally, the glass industry and also testing institutes refused to test polycarbonate glass.

Justification: The Plexiglas proportion contained oils that give off extreme smoke in fire protection tests. In addition, polycarbonate glass would be 2-3 times more expensive than standard fire protection glass, and is therefore not taken into consideration.


Information

In 2015, Schüco tested such a glass on an ad hoc basis such and the smoke development was limited.

The use of polycarbonate-glass has since been tested up to RC2 and is admissible.


EN 179 RC2

Here, polycarbonate glass or a non-transparent filling must anyway be used.


EN 1125 RC2 - Variant 1

Use of polycarbonate glass or non-transparent filling.


EN 1125 RC2 - Variant 2

The Schüco EVT panic bar was added to the programme as an alternative. This item, which can be used simultaneously as emergency exit protection, cannot be defeated by the aforementioned tricks (wires through the base or through the glass) due to the electrical barrier and so it is permissible for RC2.


Also to be noted in addition

According to the drawings KM 05.15 from Z-6.20-1888 (Schüco production catalogue 3-1.1 07.2016) and KM 05.16 from Z-6.20-1888 (Schüco production catalogue 3-1.1 07.2016) for single-leaf doors, the lower door rebate is made extremely narrow (3.5 mm inside and/or 4.0 mm outside) and in this way the door element is secured.