Schüco FW 50+ BF EI30/EW30

  • Fire protected façade with 50 mm face width
  • classification report for EI 30 and EW 30
  • Can be used for vertical and roof areas
  • Can be used as a curtain wall façade
  • High thermal insulating fire protection package
  • Maximum glass sizes 1500 mm x 3000 mm
  • Visually compatible with standard façade Schüco FW 50+
  • Fire protected window Schüco AWS 60/70 FR 30 can be used
  • Fire rated door Schüco ADS 80 FR 30 can be used
  • Burglary protection rating up to RC 2 

Schüco Façade FW 50+ BF: Fire protected façade for 30 minute fire resistance

The multifunctional fire protected façade Schüco FW 50+ BF is universally compatible with all vertical façades and skylights of fire resistance classes EI30. Thanks to identical interior and exterior face widths it can be combined seamlessly with the Schüco façade system FW 50+. With the Schüco FW 50+ BF fire protected façades floor heights up to 5000 mm can be bridged easily. In conjunction with Schüco ADS 80 FR30 doors floor heights up to 4500 mm can be executed. Skylight constructions can be implemented as saddle or pent roof with the fire protected system Schüco FW 50+ BF. ​

 

System features

SystemFacades and Skylights
Security systems
MaterialAlumínium
EnergyThermally insulated (1,3 ≤ Uf ≤ 2,0)
TypesFixed glazing
Transom and mullion
SecurityBurglar resistant RC2
Fire protection
SurfaceAlu crude (refinementable)
Sound insulationincreased sound insulation 38 - 45 dB
Key figuresThermal insulation Uf in W/m²K: from -1,0 to -1,0
Sound insulation Rᵥᵥ,ₚ in dB: from -1,0 to -1,0
Powder: all Variations
Eloxal: all Variations
Wet coating: all Variations
Stainless steel look: all Variations
Fire protection class: EI30

Exterior window element with surrounding fixed fields
For openable elements, a CE marking can be created.                                                     CE or ÜA          CE from 01.10.2019 "a must"
If an openable element has been tested in an associated supporting structure,
(same glass, same construction) and left or right or up or down a fixed field is
connected, then it is a portal → CE                                                                                   CE or ÜA          CE from 01.10.2019 "a must"
If further fixed elements are installed, then these are to be marked ÜA .                          ÜA

Exterior window element standing alone
Marked with either CE or ÜA, where: CE as a "can" rule                                                   CE or ÜA          CE from 01.10.2019 "a must"

Exterior door element standing alone
Marked with either CE or ÜA, where: CE as a "can" rule                                                   CE or ÜA          CE from 01.10.2019 "a must"

Exterior door element with Fixed Panel (as Portal)
Schüco ADS 80 FR60: see order catalogue chapter "outdoor application"                      CE or ÜA          CE from 01.10.2019 "a must"
Schüco ADS 80 FR30: Permitted based on the information in Schüco ADS 80 FR60      CE or ÜA          CE from 01.10.2019 "a must"
If further fixed elements are installed, then these are to be marked ÜA .                          ÜA

Façade element with insert element
If an external (door) element has been tested together with the façade, then                  CE or ÜA          CE from 01.10.2019 "a must"
the supporting structure is an essential component. Door CE ("can"), Façade CE

Additional information on façades
A special feature in AT is that there are no complete fire protection façades, but usually only sections.
This means that in these cases a ÜA marking is required.
Open elements with a closed system cannot be checked and a CE marking is therefore inadmissible (e.g. balconies).