SchücoFlam® CLT

  • Completely heat-insulating transparent EW safety glass
  • Space integrity and reduction of radiated heat (EW 30 to EW 120)
  • Up to 15 minutes room integrity and insulation (EI 15) max. ºT = 140 K
  • In triple insulating glass Ug-values up to 0.5 W/m²K are possible
  • Large glazing dimensions are possible - please see our documentation
  • Approved for both Schüco and Jansen systems
  • Particularly robust during transport, handling and installing due to ESG-construction
  • UV-resistant
  • Can be combined in numerous variations with other glasses in multifunctional ways.
  • Two-sided safety glazing according to EN 12600 class 1(B)1

Product description, properties and application

SchücoFlam® CLT consists of two ESG panes which are joined by a transparent alkaline interlayer which foams in the case of fire. If the interlayer is exposed to fire, it becomes opaque, foams and creates an insulating heatshield. 

The transmission of radiant heat is substantially reduced - for a certain time (ca. 15 minutes) even the insulating criteria are fulfilled. The interlayer creates a room-protection barrier against fire, smoke and heat, toxic gases, and holds for up to 120 mintes depending on the design. The foamed interlayer prevents a view of the fire, and avoids panic reactions. It also alerts the emergency services to the location of the fire.

SchücoFlam® CLT is suitable for internal as well as external use. It can be used in fire protection doors, separating walls, fire protection windows, facades, and roof constructions.​

Rapid and reliable delivey

The production leadtimes for SchücoFlam® C are projected by us and kept as short as possible - please contact us.

System features

SystemSecurity systems
MaterialGlass
TypesFixed glazing
SecurityBurglar resistant RC2
Burglar resistant RC3
SurfaceOther
Sound insulationincreased sound insulation 38 - 45 dB
Key figuresFire protection class: EW30-EW120

Exterior window element with surrounding fixed fields
For openable elements, a CE marking can be created.                                                     CE or ÜA          CE from 01.10.2019 "a must"
If an openable element has been tested in an associated supporting structure,
(same glass, same construction) and left or right or up or down a fixed field is
connected, then it is a portal → CE                                                                                   CE or ÜA          CE from 01.10.2019 "a must"
If further fixed elements are installed, then these are to be marked ÜA .                          ÜA

Exterior window element standing alone
Marked with either CE or ÜA, where: CE as a "can" rule                                                   CE or ÜA          CE from 01.10.2019 "a must"

Exterior door element standing alone
Marked with either CE or ÜA, where: CE as a "can" rule                                                   CE or ÜA          CE from 01.10.2019 "a must"

Exterior door element with Fixed Panel (as Portal)
Schüco ADS 80 FR60: see order catalogue chapter "outdoor application"                      CE or ÜA          CE from 01.10.2019 "a must"
Schüco ADS 80 FR30: Permitted based on the information in Schüco ADS 80 FR60      CE or ÜA          CE from 01.10.2019 "a must"
If further fixed elements are installed, then these are to be marked ÜA .                          ÜA

Façade element with insert element
If an external (door) element has been tested together with the façade, then                  CE or ÜA          CE from 01.10.2019 "a must"
the supporting structure is an essential component. Door CE ("can"), Façade CE

Additional information on façades
A special feature in AT is that there are no complete fire protection façades, but usually only sections.
This means that in these cases a ÜA marking is required.
Open elements with a closed system cannot be checked and a CE marking is therefore inadmissible (e.g. balconies).