Schüco ADS 65.NI SP/Sm

  • Narrow profile face widths
  • Fully tested door-wall range
  • Stable single chamber hollow profiles, with construction depth of 65mm
  • Aluminium and stainless roller clamping straps
  • Symmetrical or asymmetrical glass arrangement possible
  • Clear door passageway height tested up to 2988 mm
  • Quick clampable fastening of fittings
  • Integrated door closers possible
  • Access control and escape door security possible
  • Burglary protection rating up to RC 2 

Schüco ADS 65.NI SP (non insulated smoke control) for smoke protected door elements

Schüco ADS 65.NI SP has been tested for single and double leaf doors in accordance with 1634-3. The uninsulated smoke protection system provides specifically for indoor use variable solutions for wall and door constructions including multifunctional doors. The basis of smoke protection system Schüco ADS 65.NI SP are highly stable, uninsulated aluminum profiles with a construction depth of 65 mm. The system perfectly combines the requirements of smoke protection with multifunctional properties: soundproofing, anti-panic, access control and Burglary protection rating up to RC 2. ​

 

System features

SystemDoors
Security systems
Building extension
MaterialAlumínium
EnergyNot insulated ( Uf ≥ 2,0)
TypesFixed glazing
Supply air
SecurityBurglar resistant RC2
Burglar resistant RC3
Fire protection
Protection class
FeaturesMotorisable
Controllable
Comfort control
Radio system
Emergency Exit Control
Emergency Exit Lock
Panic function
Self-closing function
ControlManuell switchable
Electric switchable
DesignStandard
SurfaceAlu crude (refinementable)
Sound insulationincreased sound insulation 38 - 45 dB
Key figuresThermal insulation Uf in W/m²K: from -1,0 to -1,0
Sound insulation Rᵥᵥ,ₚ in dB: from -1,0 to -1,0
Burglar resistance RC: from RC2 to RC3
Powder: all Variations
Eloxal: all Variations
Wet coating: all Variations
Stainless steel look: all Variations
Smoke protection class: Sm

Exterior window element with surrounding fixed fields
For openable elements, a CE marking can be created.                                                     CE or ÜA          CE from 01.10.2019 "a must"
If an openable element has been tested in an associated supporting structure,
(same glass, same construction) and left or right or up or down a fixed field is
connected, then it is a portal → CE                                                                                   CE or ÜA          CE from 01.10.2019 "a must"
If further fixed elements are installed, then these are to be marked ÜA .                          ÜA

Exterior window element standing alone
Marked with either CE or ÜA, where: CE as a "can" rule                                                   CE or ÜA          CE from 01.10.2019 "a must"

Exterior door element standing alone
Marked with either CE or ÜA, where: CE as a "can" rule                                                   CE or ÜA          CE from 01.10.2019 "a must"

Exterior door element with Fixed Panel (as Portal)
Schüco ADS 80 FR60: see order catalogue chapter "outdoor application"                      CE or ÜA          CE from 01.10.2019 "a must"
Schüco ADS 80 FR30: Permitted based on the information in Schüco ADS 80 FR60      CE or ÜA          CE from 01.10.2019 "a must"
If further fixed elements are installed, then these are to be marked ÜA .                          ÜA

Façade element with insert element
If an external (door) element has been tested together with the façade, then                  CE or ÜA          CE from 01.10.2019 "a must"
the supporting structure is an essential component. Door CE ("can"), Façade CE

Additional information on façades
A special feature in AT is that there are no complete fire protection façades, but usually only sections.
This means that in these cases a ÜA marking is required.
Open elements with a closed system cannot be checked and a CE marking is therefore inadmissible (e.g. balconies).