Schüco FW 50+ SG

  • ​Structural Glazing façade for double and triple glazing
  • Highly thermal insulated SI insulators for excellent thermal insulation
  • 3 design variants: shadow joint, dry and wet sealed flush joint
  • Integration of Schüco AWS 114 as projected top-hung or parallel vent window
  • Large surface automated window solutions for standard and RWA
  • Burglary protection rating RC 2
  • Special steel spacer for gas-tight edge seal
  • Glass dimensions (W x H) up to 2600 mm x 4200 mm
  • Glass thickness ranges of 32 mm to 64 mm; pane weights up to 650 kg 

Elegant all-glass façade at passive house standard

The profiles of the façade are only visible in the room, outside flush all-glass appearance with elegant joints.
Highly thermal insulated insulators and triple insulation glazing ensure lowest Ucw values up to passive house standard.
The system also allows designing of the façades in Semi Structural Glazing look.
  
The window insert elements Schüco AWS 114, AWS 114 SG, AWS and AWS 114.SI and AWS 114 SG.SI fit homogeneously into the all-glass façade: as outward opening projected top-hung or parallel vent windows, can be operated manually or through Schüco TipTronic.
 
European Technical Approval (ETA 05/0114) for Structural Glazing façades; approvals for Schüco FW 50+ SG.SI are currently in process. ​

 

System features

ProduktFacades and Skylights
WerkstoffAlumínium
EnergieThermally insulated (1,3 ≤ Uf ≤ 2,0)
ProduktTypTransom and mullion
Transom and mullion-construction/Glittering glass façade
Wintergarden
SicherheitsmerkmaleBurglar resistant RC2
FunktionRaised sound insulation
Fall protection
Gestaltung/DesignStandard
Multi Countour
Structural Glazing
Semi Structural Glazing
OberflächeAlu crude (refinementable)
Schallschutzincreased sound insulation 38 - 45 dB
increased sound insulation more than 45 dB
Standard up to 38 dB
Key figuresThermal insulation Uf in W/m²K von: 1,6
Thermal insulation Uf in W/m²K bis: 1,9
Schalldämmung Rw,p in dB von: 38,0
Schalldämmung Rw,p in dB bis: 46,0
Pulver: all Variations
Eloxal: all Variations
Nasslack: all Variations
Edelstahllook: all Variations
Luftdichtheit: AE 1200
Schlagregendichtheit: RE 1050RE 1200
Stoßfestigkeit: a.A.

Schauraum

1) Delivery status
Schüco profiles for the SG version are delivered with a special anodised surface.
The special anodising provides a specially compacted surface on which adhesives hold particularly well.
Only a few companies in Europe are certified to carry out this anodising surface.

2) "Expiration date" of the surface
For SG profiles, it is important to note that the anodised surfaces have an expiration date.
Use after expiration is only possible after consultation with Schüco or AluKönigStahl.

3) Exceptions
If inadvertently raw goods are delivered, further measures are only permitted in coordination with Schüco or AluKönigStahl.
Projects without special anodising are possible if positive tests have been carried out in advance with the adhesive manufacturer.
Area of responsibility: Adhesive manufacturer or gluing operation

4) Contract
Prior to delivery of SG materials, an SG contract must be concluded between the company being supplied by AluKönigStahl and AluKönigStahl. The supplied operation may be a metalworking or a glazing operation.
The contract regulates the liability issue. Liability for damage caused by faulty SG bonding is generally the responsibility of the bonding operation. This must be tested and certified (Conformity procedure 1, ETAG 002 Regulation).