Schüco DCS Touch Display

  • Display harmoniously integrated into the profile: emphasis on elegant door appearance
  • Designed ergonomically appealing design
  • Glass-surface in high quality, unobtrusive appearance
  • Kinematic scroll operation of the bell list
  • Two outputs of the control unit freely configurable, e.g. for electric opener and alarm system
  • Display of door communication in automation systems
  • Schüco DCS proximity switch for door release on the inside is compatible
  • Escape door solution available in Schüco DCS optics
  • Communication between the display and the door switch box Is encrypted
  • Display is "wedded" to switchbox
  • Theft protection for the display mechanical and acoustic
  • Use in residential and commercial buildings
  • Delivery in projects with Intercom Client
  • Access control and door communication integrated into a single module
  • Connections directly on the Touch Screen, e.g. e-opener (recommended for interior doors)
  • Use of switchbox with cable to Touch Screen
  • Alignment also possible later 

Schüco DCS Touch Display: Door communication and access control in a single module – with the simplest IP based networking

Thanks to open IP interfacing the Schüco DCS Touch Screen can be integrated into almost any building with IP network without limitation. The door communication is possible through SIP-enabled devices like SIP installations and phones. The access module provides access management with assigning of individual numerical codes to access-authorized people, which can be switched, for example, depending on time and weekdays. People without access code can sing-in through the Touch Screen bell push buttons.

​The Schüco DCS Touch Display is a preconfigured system, optimized for use in the outdoor area.

 

​Das Schüco DCS Touch Display ist ein vorkonfiguriertes System, optimiert für den Einsatz im Außenbereich.

System features

SystemBuilding automation
Fittings and equipment
MaterialAlumínium
FeaturesComfort control
Schüco Door Control System DCS
Access control
Schüco Card-reader
ControlElectric switchable

​Please choose the respective current firmware / software versions (see "Update") according to your product.

We also make a point of listing the historical versions (see "Expired") in this directory - if available.

1) Schüco DCS TouchDisplay

   Current

     Schüco DCS TouchDisplay Firmware-Update (Version 02.00.157) 2018-11-23.zip

     Schüco DCS TouchDisplay Bedienungsanleitung (DE-DE) 2018-07-03.pdf

    Schüco DCS SmartTouch Qucik Guide Inbetriebnahme (DE-DE) 2020-03-23.pdf

   Expired

     Schüco DCS TouchDisplay Firmware-Update 2017-04-25.zip

​The Schüco internal call station, item no. 263 204, works with analogue audio and video signals.

The Schüco internal call station, item no. 263267, works via VoIP (Voice over IP).

Only the latter device is compatible with the Schüco DCS TouchDisplay.


We are looking for an affordable alternative to 263267 (similar to 263204), at the latest by December 2017.

Until then, Schüco recommends the following devices: GXV3240, GXV3275 or Luna series (Android V5).


For your information, see :System components tested by Schüco


A) Schüco DCS TouchDisplay (DCS ... Door control system)


The Schüco DCS TouchDisplay can be connected only indirectly to KNX

Usually this question arises if a "GIRA home server for KNX" should be used.

Gira is mainly controlled via LAN, but less compatible with KNX, because it works with a separate GIRA protocol.

Schüco adheres to standards that cannot currently handle the Gira protocol.


Gira shows various building information (heating, humidity, temperature, light, etc.) typically on a screen in the wall, and these are controlled there.

On demand, Gira indicates the option in order to be able to actuate their door intercom. However, this applies to their own protocol (see above).


For queries in this area, Schüco recommends the following:

It is more useful if the door intercom can use a mobile phone as a monitor.

Mobile phones have better acoustics and are well suited for this purpose. 

In addition, people have their mobile phone in their pocket most of the time; the path to a mobile is thus shorter and more convenient. 

If the home server is used by a tablet or a PC, the necessary app can be installed on it for communication, such as "Commend mobile client" (for iOS, Android) or "JITSI-client" (for Windows). In this way, it can be transmitted to a screen. For more information, please contact your electrical installer.



B) Schüco DCS access control


Schüco DCS access control is (as of 01/2018) a "stand alone" product - a bus variant will be developed if necessary.

Schüco is currently planning for a universal card reader. But many access control unit manufacturers have card readers for installation in external housing in the programme. If necessary, the Schüco DCS blind module can be used for this. 



C) Schüco DCS emergency exit protection


Has 2 output contacts

This reports the state of the system. They can be read via binary inputs and further informed using EIB/KNX.

Has 2 inputs 

- such as short-term approval release (for Zuko access control) or GMA (alarm system) for opening the doors

- such as for kindergartens, other opening times can also be used here.




Summary

Schüco DCS Konnektivität zu EIB KNX (AT-DE) Stand 2018-01-15.pdf